WIKA FLC-MR
Meter run / meter tube
規格介紹:WIKA FLC-MR
Meter run / meter tube
詳細介紹:
Differential pressure flow meters are used in many industrial applications.
Features:
- • Max. operating temperature and pressure limited by material and rating
- • Suitable for liquid, gas and steam flow measurement
- • Accuracy ≤ ±1.0 % of actual flow rate
- • Repeatability of measurement 0.1 %
更多商品

WIKA FLC-FN-PIP, FLC-FN-FLN, FLC-FN-VN Venturi nozzle, Flow nozzle
It can be used in a wide variety of applications that include steam, air, water, vapour, gas, chemical substances and high temperatures. For applications with erosive media a hardened internal surface is available. Features: • Suitable for liquid, gas and steam flow measurement • Optimum solution for measuring the flow of steam • Accuracy ≤ ±0.1 % of actual flow rate • Repeatability of measurement 0.1 % • Lowest pressure loss in the family of primary flow elements
WIKA FLC-VT-BAR, FLC-VT-WS Venturi tube
The main advantages of a Venturi tube over other differential pressure flow meters are the higher pressure recovery and the lower upstream and downstream pipe requirements. Features: • Suitable for liquid, gas and steam flow measurement • Accuracy ≤ ±0.5 % of actual flow rate • Repeatability of measurement 0.1 % • Lowest pressure loss in the family of primary flow elements • Calibration may be performed if required
WIKA FLC-APT-E, FLC-APT-F Pitot tube
The pitot tube is suitable for the measurement of one-phase media which completely fill the cross-section of the pipe. The nominal sizes range from 50 ... 1,800 mm (2" ... 72"), the pipe schedule is specified by the customer. Features: • Suitable for liquid, gas and steam flow measurement • Accuracy ≤ ±2 % of actual flow rate • Repeatability of measurement 0.1 % • Ensure the lowest pressure loss in the family of primary flow elements (approx. < 1 %)
WIKA FLC-RO-ST, FLC-RO-MS Restriction orifice
Our technical department will evaluate the correct design for the restriction orifice, depending on customer requirements and flow conditions. Features: • Suitable for liquid, gas, and steam applications • Single and multi bore solutions • Multi-step executions
WIKA FLC-FC Cone flow meter
The model FLC-FC cone flow meter uses differential pressure to determine the flow in applications with limited mounting space. Features: • Suitable for liquids, gases and steam • Wide turndown • Low requirements for straight upstream and downstream pipes • Low costs and low maintenance effort
WIKA FLC-WG Wedge flow meter
The wedge flow meter is suitable for nearly all types of flow, especially for highly viscous, dirty, abrasive, slurry or muddy media, and also for flow with a very low Reynolds number of 300 up to very high Reynolds numbers of several million. Features: • Low maintenance through robust design • For highly viscous and particle-laden media • Low permanent pressure loss • For very high and very low Reynolds numbers • Bi-directional flow measurement • Per ISO 5167 part 6 (2019)
WIKA FLC-HHR-PP HHR ProPak™ flow meter for oil and gas
The HHR ProPak™ flow meter has a lower permanent pressure loss than the orifice plate or cone flow meter. This is enabled by an optimised inlet and pressure recovery cone. Features: • No need for straight upstream and downstream pipes • Highest accuracy • Energy-efficient • Flexible installation • Wide variety of applications
WIKA FLC-CO Compact orifice plate
Compact orifice plates can be used without difficulty for the measurement of liquids, gases and vapours. Features: • Compact and robust design per ISO 5167-2 • Installation between existing flanges (ASME/EN) • Complete measuring point consisting of orifice plate, valve manifold and differential pressure transmitter available • Simple installation without differential pressure lines • Accuracy ≤ ±0.5 % of the actual flow rate and a repeatability of the measurement of 0.1 %