商品名稱:
規格介紹:
WIKA FLRU-SFI
Reed level transmitter
規格介紹:WIKA FLRU-SFI
Reed level transmitter
詳細介紹:
The model FLRU level transmitter with reed-chain technology in combination with the WIKA model NETRIS®3 radio unit is used wherever web-based remote monitoring of level measurement in liquid media is desired.
Features:
- • IIoT-capable measuring instrument in combination with WIKA radio unit, model NETRIS®3
- • Process- and procedure-specific solutions possible
- • Operating limits:
- • Process temperature:T = -80 ... +200 °C [-112 ... +842 °F]
- • Operating pressure: P = vacuum to 80 bar [1,160 psi]
- • Limit density: ρ ≥ 400 kg/m3
- • Wide variety of different process connections and materials
- • Intrinsically safe version Ex i
更多商品

WIKA FLR-S, FLR-P, FLR-H Reed level transmitter
The model FLR sensors with reed measuring chain are used for level measurement in liquid media. Features: • Process- and system-specific solutions possible • Operating limits: • Operating temperature: T = -80 ... +200 °C • Operating pressure: P = Vacuum up to 80 bar • Limit density: ρ ≥ 400 kg/m3 • Wide variety of different electrical connections, process connections and materials • Optionally with programmable and configurable head-mounted transmitter for 4 ... 20 mA field signals, HART®, PROFIBUS® PA and FOUNDATION™ Fieldbus • Explosion-protected versions (option)
WIKA FLR-F Reed level transmitter
The model FLR level transmitters with reed measuring chain are used for level measurement in liquid media. Features: • Process- and procedure-specific solutions possible • Operating limits: • Operating temperature: T = -80 ... +200 °C [-112 ... +392 °F] • Operating pressure: P = Vacuum to 25 bar [362.6 psi] • Limit density: ρ ≥ 400 kg/m3 [25.0 lbs/ft3] • Wide variety of different electrical connections, process connections and materials • Optionally with programmable and configurable head-mounted transmitter for 4 ... 20 mA field signals, HART®, PROFIBUS® PA and FOUNDATION™ Fieldbus • Explosion-protected versions (option)
WIKA FLR-SC Reed level transmitter
The model FLR-SC level transmitters with reed measuring chain are used for level measurement in liquid media. Features: • Process- and procedure-specific solutions possible • Operating limits: • Operating temperature: T = -80 ... +200 °C [-112 ... +392 °F] • Operating pressure: P = vacuum to 80 bar [1,160.3 psi] • Limit density: ρ ≥ 400 kg/m3 [25.0 lbs/ft3] • Wide variety of different electrical connections, process connections and materials • 4 ... 20 mA output signal with additional Bluetooth® interface for wireless configuration and level monitoring
WIKA FLM-CA Magnetostrictive level transmitter
The model FLM-CA magnetostrictive level transmitter is used for the high-accuracy, continuous level detection of liquids It can be used in applications with vibrations up to 4 g. Features: • Compact and space-saving design • Output signal 4 ... 20 mA (NAMUR NE43) or HART® ver. 6 • Operating limits: • Operating temperature: T = -40 ... +250 °C • Operating pressure: P = Vacuum to 40 bar • Limit density: ρ ≥ 580 kg/m3 • Explosion-protected version (option) • Vibration resistant version (option)
WIKA FLM-CM Magnetostrictive level transmitter
The model FLM-CM magnetostrictive level transmitter is used for the high-accuracy, continuous level detection of liquids in industrial applications. Features: • Compact and space-saving design for industrial applications • Output signal 4 ... 20 mA (NAMUR NE43) • Operating limits • Operating temperature T = -40 ... +125 °C • Operating pressure P = Vacuum to 40 bar • Limit density ρ ≥ 680 kg/m3
WIKA FLM-H Magnetostrictive level transmitter
The model FLM-H magnetostrictive level transmitter has been specifically designed for the requirements of the pharmaceutical and biotechnology industries. Features: • Fully welded and dead-space free • Insensitive to foaming, ideal for interface measurement • High-precision level measurement: accuracy < 0.5 mm [0.02 in] • 3-A marked hygienic design
WIKA RLT-1000 Reed-chain level sensor
The model RLT-1000 level sensor has been developed for measuring the levels of liquids. The stainless steel used is suitable for a multitude of media, such as, for example, oil, water, diesel and refrigerants. Features: • Media compatibility: Oil, water, diesel, refrigerants and other liquids • Permissible medium temperature range: -30 ... +120 °C [-22 ... +248 °F] • Output signal: Resistance in a 3-wire potentiometer circuit, current output 4 ... 20 mA • Measuring principle: Reed-chain technology • Accuracy, resolution: 24 mm [0.9 in], 12 mm [0.5 in], 10 mm [0.4 in], 6 mm [0.2 in] or 3 mm [0.1 in]
WIKA RLT-2000 Reed-chain level sensor
The model RLT-2000 level sensor has been developed for measuring the level of liquids. Features: • Media compatibility: aqueous media and corrosive liquids • Wetted parts: PP or PVDF • Output signal: Resistance in a 3-wire potentiometer circuit, current output 4 ... 20 mA • Accuracy, resolution: 24 mm [0.9 in], 12 mm [0.5 in], 10 mm [0.4 in], 6 mm [0.2 in] or 3 mm [0.1 in]